ORP6XX CD
C-PVC body flat surface electrode
C-PVC double junction Flat surface electrodes
This is the rugged version of
the traditional flat electrodes
with an improved selfcleaning
effect. Installation
and maintenance are easy
due to the quick disconnect
BNC connectors. Built into the
electrode’s body is a sealed,
gel-filled double junction
reference design. This
design provides an extra
barrier against reference
side contamination and
allows the electrodes to be
used in severe applications
prolonging electrode life.
The pH-responsive flat glass
surface is placed in the center
of the measuring surface and
surrounded by the flat porous
plastic reference junction
providing an excellent sample
contact. Version with amplified
signal for long distance
connection and metal pin to
ground liquid.
A wide range of installation
accessories allows in line,
submersion or hot tap
installation
Reference | Name | Product description | product.detail.attribute.technicalFeatures | dimensionalTable | Main category | Subcategory | Sub sub category | system | Category | family | series | Features | Operative Range | Cable* | Connection | Installation | Weight (gr.) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ORP650CD | ORP6XX CD | This is the rugged version of the traditional flat electrodes with an improved selfcleaning effect. Installation and maintenance are easy due to the quick disconnect BNC connectors. Built into the electrode’s body is a sealed, gel-filled double junction reference design. This design provides an extra barrier against reference side contamination and allows the electrodes to be used in severe applications prolonging electrode life. The pH-responsive flat glass surface is placed in the center of the measuring surface and surrounded by the flat porous plastic reference junction providing an excellent sample contact. Version with amplified signal for long distance connection and metal pin to ground liquid. A wide range of installation accessories allows in line, submersion or hot tap installation | APPLICATIONS: Water & Wastewater treatment Pre-chlorination & de-chlorination Neutralization systems Water quality monitoring Ozone treatment Coolingtowers Boiler systems Bleach production Pulp bleaching Aquaculture Fruit and vegetables washing Textile Dye Process MAIN FEATURES: pH and ORP versions Flat electrodes Double junction technology Large gel reference volume High protection from process contamination Easy and quick installation system BNC connector In line, submersion or hot tap installation Low cost fittings HF option (pH) for liquids with HF (max. 2%) inside LC option (pH) on request for pure water (<100us >) | - | Automation system | Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body | pH/ORP 600 | Automation system | FLS Measurement and control Instrumentation | ph / ORP / Conductivity Electrodes | Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body | - | - | CN 653 $ CN653 TC1 | Twist-lock (BNC) | MIFV20X05 $ MIMC20X05 | 100 |
ORP650CDDA | ORP6XX CD | This is the rugged version of the traditional flat electrodes with an improved selfcleaning effect. Installation and maintenance are easy due to the quick disconnect BNC connectors. Built into the electrode’s body is a sealed, gel-filled double junction reference design. This design provides an extra barrier against reference side contamination and allows the electrodes to be used in severe applications prolonging electrode life. The pH-responsive flat glass surface is placed in the center of the measuring surface and surrounded by the flat porous plastic reference junction providing an excellent sample contact. Version with amplified signal for long distance connection and metal pin to ground liquid. A wide range of installation accessories allows in line, submersion or hot tap installation | APPLICATIONS: Water & Wastewater treatment Pre-chlorination & de-chlorination Neutralization systems Water quality monitoring Ozone treatment Coolingtowers Boiler systems Bleach production Pulp bleaching Aquaculture Fruit and vegetables washing Textile Dye Process MAIN FEATURES: pH and ORP versions Flat electrodes Double junction technology Large gel reference volume High protection from process contamination Easy and quick installation system BNC connector In line, submersion or hot tap installation Low cost fittings HF option (pH) for liquids with HF (max. 2%) inside LC option (pH) on request for pure water (<100us >) | - | Automation system | Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body | pH/ORP 600 | Automation system | FLS Measurement and control Instrumentation | ph / ORP / Conductivity Electrodes | Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body | Signal amplified | Presence of stray currents | CN 653 $ CN653 TC1 | Twist-lock (BNC) | MIFV20X05 $ MIMC20X05 | 200 |
ORP655CD | ORP6XX CD | This is the rugged version of the traditional flat electrodes with an improved selfcleaning effect. Installation and maintenance are easy due to the quick disconnect BNC connectors. Built into the electrode’s body is a sealed, gel-filled double junction reference design. This design provides an extra barrier against reference side contamination and allows the electrodes to be used in severe applications prolonging electrode life. The pH-responsive flat glass surface is placed in the center of the measuring surface and surrounded by the flat porous plastic reference junction providing an excellent sample contact. Version with amplified signal for long distance connection and metal pin to ground liquid. A wide range of installation accessories allows in line, submersion or hot tap installation | APPLICATIONS: Water & Wastewater treatment Pre-chlorination & de-chlorination Neutralization systems Water quality monitoring Ozone treatment Coolingtowers Boiler systems Bleach production Pulp bleaching Aquaculture Fruit and vegetables washing Textile Dye Process MAIN FEATURES: pH and ORP versions Flat electrodes Double junction technology Large gel reference volume High protection from process contamination Easy and quick installation system BNC connector In line, submersion or hot tap installation Low cost fittings HF option (pH) for liquids with HF (max. 2%) inside LC option (pH) on request for pure water (<100us >) | - | Automation system | Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body | pH/ORP 600 | Automation system | FLS Measurement and control Instrumentation | ph / ORP / Conductivity Electrodes | Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body | With pressurized filling gel | - | CN 653 | Twist-lock (BNC) | WT675 $ WT675 TC1 | 100 |
ORP660CD | ORP6XX CD | This is the rugged version of the traditional flat electrodes with an improved selfcleaning effect. Installation and maintenance are easy due to the quick disconnect BNC connectors. Built into the electrode’s body is a sealed, gel-filled double junction reference design. This design provides an extra barrier against reference side contamination and allows the electrodes to be used in severe applications prolonging electrode life. The pH-responsive flat glass surface is placed in the center of the measuring surface and surrounded by the flat porous plastic reference junction providing an excellent sample contact. Version with amplified signal for long distance connection and metal pin to ground liquid. A wide range of installation accessories allows in line, submersion or hot tap installation | APPLICATIONS: Water & Wastewater treatment Pre-chlorination & de-chlorination Neutralization systems Water quality monitoring Ozone treatment Coolingtowers Boiler systems Bleach production Pulp bleaching Aquaculture Fruit and vegetables washing Textile Dye Process MAIN FEATURES: pH and ORP versions Flat electrodes Double junction technology Large gel reference volume High protection from process contamination Easy and quick installation system BNC connector In line, submersion or hot tap installation Low cost fittings HF option (pH) for liquids with HF (max. 2%) inside LC option (pH) on request for pure water (<100us >) | - | Automation system | Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body | pH/ORP 600 | Automation system | FLS Measurement and control Instrumentation | ph / ORP / Conductivity Electrodes | Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body | - | - | CN 653 | Twist-lock (BNC) | EG66P $ MK660 | 100 |
ORP660CDDA | ORP6XX CD | This is the rugged version of the traditional flat electrodes with an improved selfcleaning effect. Installation and maintenance are easy due to the quick disconnect BNC connectors. Built into the electrode’s body is a sealed, gel-filled double junction reference design. This design provides an extra barrier against reference side contamination and allows the electrodes to be used in severe applications prolonging electrode life. The pH-responsive flat glass surface is placed in the center of the measuring surface and surrounded by the flat porous plastic reference junction providing an excellent sample contact. Version with amplified signal for long distance connection and metal pin to ground liquid. A wide range of installation accessories allows in line, submersion or hot tap installation | APPLICATIONS: Water & Wastewater treatment Pre-chlorination & de-chlorination Neutralization systems Water quality monitoring Ozone treatment Coolingtowers Boiler systems Bleach production Pulp bleaching Aquaculture Fruit and vegetables washing Textile Dye Process MAIN FEATURES: pH and ORP versions Flat electrodes Double junction technology Large gel reference volume High protection from process contamination Easy and quick installation system BNC connector In line, submersion or hot tap installation Low cost fittings HF option (pH) for liquids with HF (max. 2%) inside LC option (pH) on request for pure water (<100us >) | - | Automation system | Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body | pH/ORP 600 | Automation system | FLS Measurement and control Instrumentation | ph / ORP / Conductivity Electrodes | Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body | Signal amplified | Presence of stray currents | CN 653 | Twist-lock (BNC) | EG66P $ MK660 | 200 |
APPLICATIONS:
- Water & Wastewater treatment
- Pre-chlorination & de-chlorination
- Neutralization systems
- Water quality monitoring
- Ozone treatment
- Coolingtowers
- Boiler systems
- Bleach production
- Pulp bleaching
- Aquaculture
- Fruit and vegetables washing
- Textile Dye Process
MAIN FEATURES:
- pH and ORP versions
- Flat electrodes
- Double junction technology
- Large gel reference volume
- High protection from process contamination
- Easy and quick installation system
- BNC connector
- In line, submersion or hot tap installation
- Low cost fittings
- HF option (pH) for liquids with HF (max. 2%) inside
- LC option (pH) on request for pure water (<100us >)