Repair and reinforcement saddle, SDR11
Repair and reinforcement saddle RSV SDR 11
- Gas, water and H2
- Working pressure: MOP (gas) 10 bar, PFA (water) 16 bar
- Material: PE 100-RC
- 2 combined saddle components
- Safety technology
Note:
Only apply to minor pipe damage.
The damage must be located within the repair area and not in the fusion zone.
PE 100-RC SDR 11
Maximum permissible working pressure 16 bar (water) / 10 bar (gas)
| Reference | d1 | d2 | B1 | H | H | t | Weight [kg] | BX | Pallet quantity |
|---|---|---|---|---|---|---|---|---|---|
| 615164 | 90 | 50 | 155 | 148 | 148 | 21 | 0,930 | 24 | 192 |
| 615165 | 110 | 50 | 178 | 170 | 170 | 21 | 1,160 | 16 | 128 |
| 615166 | 125 | 50 | 190 | 183 | 183 | 21 | 1,370 | 15 | 120 |
| 615168 | 160 | 50 | 225 | 218 | 218 | 21 | 1,680 | 10 | 80 |
| 615169 | 180 | 50 | 240 | 238 | 238 | 21 | 1,810 | 6 | 48 |
| 615170 | 200 | 50 | 250 | 258 | 258 | 21 | 1,860 | 5 | 40 |
| 615171 | 225 | 50 | 255 | 283 | 283 | 21 | 1,910 | 5 | 40 |
Areas of Application
The FRIALEN Repair and Reinforcing Saddles are used for the repair of minor pipe damages.
FRIALEN safety fittings are fusion-capable with PE pipes according to the specifications of the SDR pipe series on the barcode sticker/datasheet of the respective fitting. The minimum wall thicknesses specified in the standards EN1555-1, EN 12201-1 and ISO 4437 must be observed.
Assembly Instructions
The fusion of the HD-PE pipe with the FRIALEN Repair and Reinforcing Saddle takes place by FRIALEN fusing – leakproof and longitudinally strong. In order to avoid discharge of media, the leak has to be sealed with a separate plug (≤ d2).
Both saddles have to prepared according to the general assembly requirements (see assembly instructions: „FRIALEN safety fittings for sustainable pipes for gas, water networks and industrial systems made of PE“) (remove/clean oxide layer from pipe).
Good reasons for using the FRIALEN VVS:
- Compact construction
- Open wire technology for direct heat transmission
- Fusion area free of heating wires
- Preassembled unit without loose parts
- Wide fusion zone
- Additional barcode for tracing back the fitting (Traceability-Coding)